PRESSURE
CONTROL TYPE MP
FUNCTION
Type MP is a Single
Pole double throw (SPDT) pressure control for stopping and starting
small refrigeration compressors using CFC, HCFC, HFC, and R717 refrigerants.
These switches are available in Low pressure, High pressure and
Combined High/Low pressure versions.
The construction is simple and sturdy. The device is enclosed in
a dust proofed mild steel casing and all parts are rust proofed
for long life. Starting and stopping pressures can be set independently
and the device has clearly read setting scale for reference.
MP series Pressure Switches find applications
in
>> Refrigeration Compressors
>> Air Conditioning Compressors
|
|
|
SPECIFICATIONS
| Enclosure
|
:
|
Mild
Steel (Zinc plated Chrome passivated.) |
| Enclosure
Protection |
:
|
IP 33,
Dust Proof |
| Sensing Element |
:
|
Phosphor Bronze bellows
(Stainless Steel bellows for ammonia) |
| Max Process Temp. |
:
|
90°C |
| Max Ambient Temp. |
:
|
-40 to 70°C |
| Switch Type |
:
|
1 SPDT |
| Switch Rating |
:
|
10 A resistive 6
A inductive 380 VAC, 0.2 A inductive 250 VDC |
| |
|
|
| ORDERING
TABLE |
|
|
|
|
|
TYPE
|
MODEL
|
RESET
|
REFRIGERANT
|
PRESSURE
RANGE
|
DIFFERENTIAL
|
MAX
PRESSURE
(atmg)
|
FUNCTION
ON
PRESSURE
INCREASE
|
CONNECTION
SIZE
|
|
LOW
STARTING
|
HIGH
STOPPING
(atmg)
|
LOW
PRESSURE
(atm)
|
HIGH
PRESSURE
(atm)
|
|
LOW
PRESSURE
CONTROL
|
MP-1
|
Auto
|
CFC,
HCFC, HFC
|
30
cm Hg
to 7 atmg
|
-
|
0.6
to 6
|
-
|
16
|
Starts
|
1/4"
flare
|
|
MP-1R
|
Manual
|
CFC,
HCFC, HFC
|
30
cm Hg
to 7 atmg
|
-
|
0.6
(Fixed)
|
-
|
16
|
Starts
|
1/4"
flare
|
|
MP-1A
|
Auto
|
R717
(NH3)
|
30
cm Hg
to 7 atmg
|
-
|
0.6
to 6
|
-
|
16
|
Starts
|
Steel
Capillary tube
|
|
MP-1AR
|
Manual
|
R
717 (NH3)
|
30
cm Hg
to 7 atmg
|
-
|
0.6
(Fixed)
|
-
|
16
|
Starts
|
Steel
Capillary tube
|
|
HIGH
PRESSURE
CONTROL
|
MP-5
|
Auto
|
CFC,
HCFC, HFC
|
-
|
6
to 30
|
-
|
3
to 8
|
32
|
Stops
|
1/4"
flare
|
|
MP-5A
|
Auto
|
R
717 (NH3)
|
-
|
6
to 22
|
-
|
2
to 8
|
32
|
Stops
|
Steel
Capillary tube
|
|
MP-5R
|
Manual
|
CFC,
HCFC, HFC
|
-
|
6
to 30
|
-
|
3
(Fixed)
|
32
|
Stops
|
1/4"
flare
|
|
MP-5AR
|
Manual
|
R
717 (NH3)
|
-
|
6
to 22
|
-
|
2
(Fixed)
|
32
|
Stops
|
Steel
Capillary tube
|
|
COMBINED
HIGH
AND
LOW
PRESSURE
CONTROL
|
MP-15
|
Auto
|
CFC,
HCFC, HFC
|
30
cm Hg
to 7 atmg
|
8
to 30
|
0.6
to 6
|
4
(Fixed)
|
16
for
low
pressure
side
32
for
high
pressure
side
|
Low
Pressure
starts
High
Pressure
stops
|
1/4"
flare
|
|
MP-15A
|
Auto
|
R
717 (NH3)
|
30
cm Hg
to 7 atmg
|
8
to 22
|
0.6
to 6
|
3
(Fixed)
|
Steel
Capillary tube
|
|
MP-15R
|
Manual
|
CFC,
HCFC, HFC
|
30
cm Hg
to 7 atmg
|
8
to 30
|
0.6
to 6
|
4
(Fixed)
|
1/4"
flare
|
|
MP-5AR
|
Manual
|
R
717 (NH3)
|
30
cm Hg
to 7 atmg
|
8
to 22
|
0.6
to 6
|
3
(Fixed)
|
Steel
Capillary tube
|
|